Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-12 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	38
Date	08/12/14
Start Time	10:36:09
Diameter Midpoint
 10.9	309.925
 11.3	18452.6
 11.8	143052
 12.2	184548
 12.6	214369
 13.1	255257
 13.6	293172
 14.1	338074
 14.6	385038
 15.1	430465
 15.7	479369
 16.3	537867
 16.8	583089
 17.5	634521
 18.1	683683
 18.8	733724
 19.5	789343
 20.2	823818
 20.9	845997
 21.7	877970
 22.5	905053
 23.3	907447
 24.1	912633
 25.0	898182
 25.9	889007
 26.9	861945
 27.9	814954
 28.9	770306
 30.0	711729
 31.1	641570
 32.2	564866
 33.4	483146
 34.6	412089
 35.9	339164
 37.2	275251
 38.5	219662
 40.0	172830
 41.4	131632
 42.9	98354.8
 44.5	72125.9
 46.1	52097.8
 47.8	37091.5
 49.6	26117.4
 51.4	18657
 53.3	13154.3
 55.2	9592
 57.3	7512.25
 59.4	5372.01
 61.5	4611.86
 63.8	4033.81
 66.1	3722.98
 68.5	3674.8
 71.0	3466.28
 73.7	2859.99
 76.4	2643.16
 79.1	2405.6
 82.0	2021.45
 85.1	2054.54
 88.2	2290.44
 91.4	2418.47
 94.7	2550.35
 98.2	2649.38
101.8	2616.84
105.5	2374.69
109.4	2244
113.4	1789.18
117.6	1495.23
121.9	1199.15
126.3	935.297
131.0	868.892
135.8	628.264
140.7	533.957
145.9	472.619
151.2	425.613
156.8	259.89
162.5	219.903
168.5	168.334
174.7	184.524
181.1	151.005
187.7	117.243
194.6	106.085
201.7	105.773
209.1	126.846
216.7	76.6977
224.7	90.9695
232.9	64.976
241.4	61.0396
250.3	45.7034
259.5	50.1146
269.0	41.5856
278.8	28.3709
289.0	22.6967
299.6	29.9497
310.6	31.1506
322.0	17.9402
333.8	11.1342
346.0	7.71309
358.7	30.137
371.8	17.9547
385.4	16.45
399.5	12.3941
414.2	10.699
429.4	11.817
445.1	8.60169
461.4	9.81435
478.3	16.3065
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.1708
High Voltage	9849.73
Lower Size(nm)	10.7461
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1076.23
Median(nm)	22.9942
Mean(nm)	24.0531
Geo. Mean(nm)	22.893
Mode(nm)	24.1442
Geo. Std. Dev.	1.36267
Total Concentration(#/cm)	2.05628e+007
Comment	